PRODUCTS » DATA CABINETS » SPECIAL CABINETS » RCA
Castors
This type of cabinet is installed on castors (included in supply). Two of them are equipped with a brake.
Adjustable vertical rails
The cabinet contains two pairs of freely adjustable 19“ rails. Versions deeper than 800 mm are delivered with one additional pair of the middle vertical rails.
Breakout-type blanking panels
Cable openings covered with breakout-type blanking panels are located in the bottom and rear part of the cabinet.
Rigid construction
High quality workmanship and the most up-to-date technology ensure a perfect look of the cabinet.
Flexible door opening
The hinge system allows the door to open almost 165°. The door can be easily removed.
Glass
The full-glass doors are made of 4 mm thick tempered safety glass, which is resistant to ordinary impacts. When broken, it forms a number of small fragments like automotive glass. For safety reasons, we recommend closing the full-glass door after installing the equipment in the cabinet so that it cannot collide with other objects. Our full-glass doors are tested in a certified testing laboratory and meet the requirements of ČSN EN 12150-1+A: Glass in construction – Thermally tempered soda-lime-silicate safety glass. The tested glass meets the standard for the disintegration of glass after breakage, Certificate of Conformity CQ-24- 2023, Test Protocol IKATES 58A-2024.
Door lock
It enables easy and quick access into the cabinet.
Door
The cabinet has fully glass door as standard, however, it can be steel or perforated if required.
Fan unit installation
On the back wall is the preparation in form of break-out openings for the installation of fan units RAx-CH-X2x-X1 or fans RAX-CH-X07-X9 for wall mounting cabinet to support cooling of installed equipment (see Active cooling).
Operation conditions
Operation environment
the office
the cabinet is not intended for outdoor installations and for installations in environment that can negatively influence the functionality of the cabinet and the mounted devices (e.g. environment with danger of explosion or humid and wet surroundings).
Must be protected against
mechanical damage,
improper handling,
a different usage than the cabinet is intended for.
Improper handling is especially
overloading (exceeding the maximum recommended load),
device installation that can negatively influence the operation and function of the cabinet or the installed equipment,
change of the construction or design of the cabinet.
Installation of the cabinet
To ensure the maximum recommended load, it is necessary to distribute the load evenly.
Place the cabinet on a flat floor and adjust any differences using levelling feet.
To avoid dust penetration in case the cables lead through some of the cable openings, it is possible to seal it using a blanking panel with a brush and equip it with a hem edge (both are included in the supply).
Environmental protection
All parts are made of recyclable materials and after decommissioning the cabinet, they must be disposed of according to relevant regulations.
Certificate and conformity
This product is certified with TÜV SÜD Czech, certificate number 07.947.987, date 09/07/2015 and is fully in accordance with ČSN EN 62208 ed.2:2012 (EN 62208:2011).